The RTNT1000-C3 current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current sensor, It can really measure resolution 1000:1 and it uses for precision measurement of DC, AC and pulse current.

Electrical  data(Ta=255) 

 

Parameter

Type

RTNT1000-C3

Unit

Rated input Ipn)

10-1000

A

Measure range(Ip)

2000

A

coil resister

@ 85

47

 

 

 

Measure resister

with15V

@1000Amax

0(min)

20(max)

with15V

@1200Amax

0(min)

7.5(max)

with24V

@1000Amax

0(min)

65(max)

with24V

@2000Amax

0(min)

7.5(max)

Turns ratio(Np/Ns)

1:5000

T

Rated output (Isn)

20.2-0.3%FS(10A), 2000.2-0.3%FS(1000A)

mA

Supply voltage

1524

V

Power consumption

20+IpX(Np/Ns)

mA

Zero offset

@Ip=0

0.2

mA

Offset drift

@ -4085

0.5

mA

Response time

@100A/ S,10%-90%

1

s

Linearity

@Ip=0-Ipn

0.05

%FS

Galvanic isolation

@ 50HZ, AC, 1min

6

KV

di/dt accurately followed

100

A/s

Bandwidth

@ -3dB

DC150

KHz

Application

 

  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Battery supplied applications
  • Uninterruptible Power Supplies (UPS)
  • witched Mode Power Supplies (SMPS)
  • Power supplies for welding applications. 
Directions  for  use

 

 

  • Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
  • The primary conductor should be120.
  • The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.

Standard 

 

 

  • UL94-V0. ;EN60947-1:2004 ;IEC60950-1:2001
  • EN50178:1998 ;SJ 20790-2000

General Date

 

Operating temperature

-40+85

C

TA

Storage temperature

-40+125

C

TS

Mass(approx)

570

g

M

 

Enter Buying Requirement Details