The RTO2000HT series current sensor series is a open loop device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit, It provides accurate electronic measurement of DC, AC or pulsed currents.
Electrical data (Ta=25℃±5℃,RL=2KΩ ,CL=10000PF)
Type Parameter | RTO 200HT | RTO 400HT | RTO 500HT | RTO 600HT | RTO 750HT | RTO 800HT | RTO 1000HT | RTO 1500HT | RTO 2000HT | Unit |
Rated input (Ipn) | ±200 | ±400 | ±500 | ±600 | ±750 | ±800 | ±1000 | ±1500 | ±2000 | A |
Measure range(Ip) | ±600 | ±1200 | ±1500 | ±1800 | ±2250 | ±2400 | ±3000 | ±3000 | ±4500 | A |
Rated output | @ IP=±IPN | | ±4±1% | | | | V | |||
Supply voltage | ±15 ±5% | V | ||||||||
Consumption current | @ Is=0 | | +28,-15 | | | | mA | |||
Offset voltage | ≤±20 | mV | ||||||||
Magnetic offset | @ IP=±IPN -0 | | ±15 | | | | mV | |||
Offset drift | ≤±1.0 | mV/℃ | ||||||||
output drift | ≤±1.0 | mV/℃ | ||||||||
Linearity | @ IP=0-±IPN | | ≤1 | | | | %FS | |||
Response time | @50A/μ S, 10%-90% | | ≤5 | | | | μ S | |||
Bandwidth | @ -3dB | | DC-25 | | | | KHz | |||
Galvanic isolation | @ 50HZ/60HZ,AC,1min | | 3 | | | | KV | |||
Isolation resistance | @ DC 500V | | 1000 | | | | MΩ |